## The Selectron™ range of water softeners produce from 0.08 to 4 m3/hr of softened water.



 

 

 

 

 



 [Overview](#1) [Applications](#2) [Services](#3) [Product range and Resources](#4) 

 

 

## Overview

 

 

 

The flexible design and programming features of the Selectron™ systems means that they can be easily configured to meet individual site requirements, thus providing a cost efficient, reliable and easy-to-use solution to the problems associated with hard water.

**Applications**

- Boiler Feed
- Glass Washing
- General Manufacturing

**FEATURES AND BENEFITS**

- The Selectron™ utilises a fully programmable and flexible microprocessor control system with an easy -to-read LCD display to provide constant system status
- Selectron™ units can be upgraded by using the same control, common to the entire range. Similarly, Timelock systems can be easily upgraded to Watermeter operation
- Simple to programme and use; softener regeneration is automatically controlled and initiated
- The advance control systems ensure that optimum performance is achieved from the softeners, thus maximising water savings and minimising salt usage
- Choice of Timeclock or Water operation
- The control head operates on 24 volts to ensure safe installation, operation and maintenance
- All units in the range are supplied'off the shelf' for quick, easy and low cost installation and start up
- Proven design and materials of construction ensures operational reliability
- Solenoid valve prevents hard water to service during regeneration (optional)



 

 

 



 

 

 

## Applications

 

 

 

**System Performance**

| Model |  | 15 | 30 | 50 | 80 |
|---|---|---|---|---|---|
| Maximum treated water flow | m3/hr | 1.0 | 2.4 | 3.2 | 4.0 |
| Optimum treated water flow | m3/hr | 0.7 | 1.6 | 2.1 | 2.7 |
| Minimum treated water flow | m3/hr | 0.08 | 0.12 | 0.15 | 0.25 |
| Regeneration time | mins | 24 | 38 | 56 | 83 |
| Maximum flow to drain | m3/hr | 0.37 | 0.60 | 0.75 | 1.25 |
| Efficient Volume | m3 | 0.17 | 0.23 | 0.32 | 0.45 |
| Pressure loss at max flow | bar | 0.25 | 1.67 | 2.8 | 3.40 |
| Salt Usage Per Regeneration | Kg | 1.95 | 3.90 | 6.50 | 10.40 |



**Volume of Softened Water Per Regeneration**

| Model |  | 15 | 30 | 50 | 80 |
|---|---|---|---|---|---|
| Raw Water-Soft 100 mg/l | m3 | 8.20 | 16.50 | 32.50 | 52.00 |
| Raw Water-Average 200 mg/l | m3 | 4.10 | 8.25 | 16.25 | 26.00 |
| Raw Water-hard 400 mg/l | m3 | 2.00 | 4.12 | 8.12 | 13.00 |



*(Note: volumes stated above are based on systems running at optimum flow rates)*

**System Dimensions**

| Model |  | 15 | 30 | 50 | 80 |
|---|---|---|---|---|---|
| Height | mm | 1110 | 1120 | 1605 | 1577 |
| Depth | mm | 575 | 575 | 575 | 575 |
| Width | mm | 760 | 760 | 760 | 760 |
| Recommended Headroom | mm | 500 | 500 | 500 | 500 |
| Approx. Shipping Weight | kg | 60 | 70 | 90 | 145 |
| Approx. Service Weight | kg | 200 | 240 | 275 | 400 |





 

 

 



 

 

 